Detailed introduction
BL-12
Copper Removing Agent on Iron
It is made up by high purity chemicals, to peel off copper plating layer on iron in the way of electrolysis, while cause no corrosion to substrate. Composition Range Unit
BL-12A Copper Removing Agent  200-300 ml/L
Temperature 20-40 °C
Current Density 10-20 A/dm2
Anode: Cathode( Area Ratio) 1:2-2.5
Peeling Rate 0.7-2.5um/min
PH Value 5-7 V